100% expanded PTFE (polytetrafluoroethylene), with multidirectional strength. Chemical resistance to all media pH 0-14, except molten alkali metals and elemental fluorine.

The maximum applicable pressure and temperature depend mainly on the equipment and installation.
  • Typical use: -60°C to 230°C (-76°F to 445°F); industrial full vacuum(1) to 40 bar (580 psi)
  • Maximum use: -269°C to 315°C (-452°F to 600°F); full vacuum to 210 bar (3000 psi)
For applications outside the typical use range, Gore recommends an application specific engineering design calculation and extra care during installation. Also, consider retorquing after a thermal cycle when the equipment has returned to an ambient temperature condition. Please contact Gore if further guidance is required.
(1) absolute pressure of 1 mmHg(Torr) = 133 Pa = 1.33 mbar = 0.019 psi 
For industrial use only. Not for use in food, drug, cosmetic or medical device manufacuring, processing or packaging operations.